Control Cable

UL 2464

Brand: RR Kable

Technical Specifications

Feature Specification
Standard: UL- Std. 758. Special PVC command cable, approved to UL-Style 2464, cores according to AWG 24-16 to UL-Style 1007/1569
Nominal Voltage: 300V
Test Voltage: 1500V
Break down Voltage: Min. 3000V
Temperature Range: Flexible -10°C to +80°C. Fixed installation -20°C to + 80°C
Minimum Bending Radius: Flexing approx. 15x cable ø

Application

Suitable for use as a command, measuring and control cable in tool making machinery conveyor system and production lines, in industrial plants and in air conditioning as well as in the steel producing industries.


Cable Construction

    • Annealed Plain copper, fine wire conductors AWG 24 -16, Table 30.3 UL 1581 ASTM – B.
    • Conductor make – up to.
    • 0.22 Sq. mm = 8 x 0.187mm
    • 0.44 Sq. mm = 16 x 0.187 mm
    • 0.66 Sq. mm = 24 x 0.187 mm
    • 0.88 Sq. mm = 32 x 0.187 mm
    • 1.30 Sq. mm = 30 x 0.235 mm
    • Special PVC core insulation class 43, semirigid to UL- Std. 1581 table 50.182 and 50.183.
    • Colour coded to H05VV – F up to 5 cores coloured black with numbers for above 5 cores.
    • Cores stranded in layers with optimal lay-length.
    • Special PVC outer jacket class 43 to UL – Std. 1581 table 50.182.
    • Outer jacket colour black or grey.

    Properties

    • PVC self-extinguishing and flame retardant, test method VW-1, FT 1

    Cable Design Parameters

    Kindly complete the part numbers for these cables by adding the suffix (in place of ‘z’) for the sheath colour required: 1 – black (RAL 9005), 3 – grey (RAL 7001)

    Related Product

    RR Kable

    JZ-500

    • Uo / U 300 / 500V
    • Min. 20 GΩ x cm
    • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
    RR Kable

    Control Cable (IS 694)

    • IS 694 marked, FIA/TAC
    • Electrolytic grade annealed copper Class-5 as per IS 8130, having uniform resistance properties
    • All black colour cores with continous white numbering, gn-yl core on outer most layer for earth if applicable
    RR Kable

    JZ-CY

    • Uo / U 300 / 500V
    • Min. 20 GΩ x cm
    • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
    RR Kable

    JZ-YCY

    • Uo /U 300 / 500V
    • Min. 20 GΩ x cm
    • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
    RR Kable

    JZ-YSY

    • Uo / U 300 / 500V
    • Min. 20 GΩ x cm
    • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
    RR Kable

    JB-YCY

    • Uo / U 300 / 500V up to 1.5 mm². Uo / U 450 / 750V for 2.5 mm² and above
    • Min. 20 GΩ x cm
    • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C