Control Cable

JB-YCY

Brand: RR Kable

Technical Specifications

Feature Specification
Nominal Voltage: Uo / U 300 / 500V up to 1.5 mm². Uo / U 450 / 750V for 2.5 mm² and above
Insulation Resistance: Min. 20 GΩ x cm
Temperature Range: Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
Minimum Bending Radius: Flexing 20 x cable ø. Fixed installation 6 x cable ø
Test Voltage: 4000V
Breakdown Voltage: Min. 8000V
Mutual Capacitance (0.5 to 2.5 Sq. mm): core to core (approx.) – 150 nF/km core to screen (approx.) – 270 nF/km

Application

For use as a data and control cable in machinery, computer systems etc. as well as a signal cable for electronics. The high level of screening ensures a high degree of interference protection. The dense screening assures disturbance-free transmission of all signals and impulses. The PVC-inner sheaths of these cables raise the mechanical strength. The applied clear transparent PVC outer sheath accentuates the optical view of the tinned copper braid. These cables are suitable for flexible use for medium mechanical stresses with free movements.

Standard

Adapted to DIN/BS EN 50525-2-51.


Cable Construction

Bare copper, fine wire conductors, EN 60228 Cl. 5.
Core insulation of TI2, EN 50363-3.
Core identification : As per VDE 0293-302/HD 308 S2 (Refer appendix table No. 1-1)
Green/yellow earth core in outer layer (3 cores and above).
Cores stranded in layers with optimal lay-length.
Special PVC inner jacket.
Tinned copper, braided screen, approx 85% coverage.
Transparent special PVC outer sheath.

Properties

  •  PVC self-extinguishing and flame retardant according to EN 60332-1-2.
  • EMC: Electromagnetic compatibility
  •  To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.

Related Product

RR Kable

JZ-500

  • Uo / U 300 / 500V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kable

Control Cable (IS 694)

  • IS 694 marked, FIA/TAC
  • Electrolytic grade annealed copper Class-5 as per IS 8130, having uniform resistance properties
  • All black colour cores with continous white numbering, gn-yl core on outer most layer for earth if applicable
RR Kable

JZ-CY

  • Uo / U 300 / 500V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kable

JZ-YCY

  • Uo /U 300 / 500V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kable

JZ-YSY

  • Uo / U 300 / 500V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kable

JB-YCY

  • Uo / U 300 / 500V up to 1.5 mm². Uo / U 450 / 750V for 2.5 mm² and above
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C