Acti9 Active ICV40 VigiARC

A9TDNC616

Brand: Schneider

Technical Specifications

Feature Specification
Range Acti9
Product name Acti9 Active iCV40 ARC
Product or component type Active arc fault detection RCBO
Device short name iCV40N ARC
Product specific application Arc fault detection
Standards EN/IEC 62606 / EN/IEC 61009-1 / EN/IEC 61009-2-1
Poles description 1P + N
Number of protected poles 1
Curve code C
Breaking capacity code N

Active arc fault detection RCBO, Acti9 Active iCV40N ARC, 1P+N, 16A, C curve, 30mA, type A-SI, 6000A

Experience optimal protection for final circuits against overcurrents and insulation faults with Acti9 Active iCV40N ARC Active 1P+N 16A Active arc fault detection RCBO. It has a C tripping curve and operates at a reliable network frequency of 50Hz. Featuring a 30mA earth leakage sensitivity and instantaneous detection to protect from electrical hazards, Its A-SI type provides increased immunity from electrical interference and polluted or corrosive environments. Its rated short circuit breaking capacity goes up to 6000A at 230VAC conforming to IEC 61009-2-1 standard. The device provides comprehensive protection against short circuits, cable overload, and electrical shock by direct and indirect contact. Elevate your energy management with Acti9 Active products, seamlessly communicating with the gateways EcoStruxure Panel Server Entry, Universal, and Advanced. It has a proactive safety with an advanced pre alarming system that warns about overload, earth leakage, and overvoltage. It also measures internal temperature, Power Factor, and time of use. Maximize efficiency with 2 unique VISI-TRIP indicators that minimize intervention time by displaying earth leakage, arc, overload, and short-circuit fault tripping. It also allows for quick identification of issues. Additionally, its limitation class 3 improves downstream circuit protection cost. The device can be clipped on a DIN rail, and its width is 4 pitches of 9mm. It has an IP20 degree of protection on its terminals. The device complies with EN/IEC 61009-1, EN/IEC 62606, and EN/IEC 61009-2-1 standards. It operates in temperature between -25°C to 50°C.

Related Product

Schneider

A9TDNC606

  • Acti9
  • Acti9 Active iCV40 ARC
  • Active arc fault detection RCBO
Schneider

A9TDNC610

  • Acti9
  • Acti9 Active iCV40 ARC
  • Active arc fault detection RCBO
Schneider

A9TDNC610

  • Acti9
  • Acti9 Active iCV40 ARC
  • Active arc fault detection RCBO
Schneider

A9TDNC616

  • Acti9
  • Acti9 Active iCV40 ARC
  • Active arc fault detection RCBO
Schneider

A9TDNC625

  • Acti9
  • Acti9 Active iCV40 ARC
  • Active arc fault detection RCBO
Schneider

A9TDNC632

  • Acti9
  • Acti9 Active iCV40 ARC
  • Active arc fault detection RCBO